Gas station image maintenance standard 2019-02-25
Image maintenance standard
1. The gas station image maintenance project mainly includes key parts such as shed sheds, shed ceilings, wall exterior façades, fueling areas, convenience stores, oil tank areas, lamps, signage signs, advertisements, etc.
2. The overall image of the gas station should be neat and tidy, and the signage should be made without damage or fading.
3. The image maintenance of the gas station is included in the scope of supervision and assessment.

Outdoor image standard
1. Outdoor area division
The outdoor image of the gas station includes three areas: the fueling area, the oil tank area and the auxiliary area.
Among them: the fueling area includes a shed, a column, a tanker, a refueling island, and a refueling area;
The oil tank area includes an oil discharge area, an operation well, an oil tank area attachment, and a tank area;
Auxiliary areas include green belts, parking areas, sanitary ware placement areas, other auxiliary areas, and service areas such as clothing and catering.
The identification signs in the fueling area, the oil tank area and the auxiliary area include identification signs, warning signs, billboards, price plates, and guide signs.
2. Overall requirements for outdoor image
Gas station outdoor buildings, equipment and facilities should be maintained in time, keep clean and beautiful, no damage, no fading; signs, signs, billboards to make the fonts eye-catching, complete, unobstructed, no damage, no fading, not hanging, painting Posting; items are placed neatly and orderly.
3. Gasing area
1) Do not place any debris on the top of the tanker; the grease gun should be kept clean and free of stains; after the fuel is added, the grease gun hose should be plated and hung on the hose hook.
2) A multi-function cleaning service desk, multi-functional safety service desk or fire-fighting equipment can be placed on the refueling island.
3) The surface of the fueling area should be flat, no damage, no obvious oil pollution, no water accumulation; the ground markings are clear; the placement of on-site items does not affect the passage of vehicles; the fire passages are unblocked and unobstructed.
4, oil tank area
1) The electrostatic grounding clamp and the connecting wires of the unloading area are placed in a special box; the fire-fighting equipment is placed neatly at the designated position; the unloading port, the fire-fighting sand pool, and the fire-fighting equipment room are intact and intact.
2) The operation well is clean and tidy, no oil, no water accumulation, the manhole cover is intact, the tank number and the oil product label are bold and clear.
3) There is no debris in the tank area, no water accumulation, no weeds.
5, auxiliary area
1) There are no weeds and no garbage in the green belt, and the green plants are trimmed neatly, and the dead plants and flowers are cleared in time.
2) The parking area markings are clear and the vehicles are parked neatly; external vehicles are forbidden to park in the station for a long time.
3) Sanitary ware should be stored neatly in the designated concealed area, keeping it clean and tidy.
4) The appearance of the building for steam service and catering should be neat and tidy, the operation and service facilities are intact, the items are placed neatly, and the indoor and outdoor venues are kept flat, clean and free of accumulated water.
6, identification signs
1) The identification signs should be firmly installed and posted according to the specified location. The temporarily added identification signs should be submitted to the relevant higher authorities for approval before they can be placed.
2) Advertising advertisements in the station must be posted at the designated location; temporarily added advertisements should be reported to the higher authorities for approval; the advertising content should be complete, and the advertisements should be replaced in time due to expiration and damage. The advertisements operated by others are managed according to our image standards.
3) Mobile billboards and guide signs should be placed in designated and conspicuous positions without affecting vehicle traffic.

Indoor image standard
1. The indoor image range of the gas station includes the business room, convenience store, office, living room, auxiliary room, toilet and lighting. Among them: living room includes staff quarters, kitchen, activity room, bathroom, dressing room; auxiliary rooms include power distribution room, boiler room, customer lounge, warehouse and so on.
2, the overall requirements of the indoor image: indoor equipment, items placed in the specified position, keep neat.
3. Indoor equipment and articles should be regularly maintained to ensure that equipment and articles are clean and tidy; equipment and articles should be repaired and replaced in time.
4, business rooms, offices can only be placed in the work equipment, items, equipment, items should be uniform specifications, colors.
5. The business licenses to be publicized at the gas station shall be uniformly and uniformly hoisted in suitable indoor locations; business licenses that do not need to be publicized shall be stored in the designated location.
6, the convenience store layout should meet the planning and design requirements, advertising, posters, etc. posted in an orderly manner.
6, the items in the living room are neatly arranged, and the daily necessities should be uniformly arranged, uniform specifications, and colors.

Toilet management
1. The gas station must establish a toilet hygiene responsibility system to clarify the person responsible for toilet hygiene and cleaning requirements.
2. The toilet inside the station is open to the public.
3, the toilet should be set up with eye-catching signage, equipment and equipment in the toilet are well equipped.
4, the toilet should be kept ventilated, no obvious odor, dirt, water; lighting, water supply facilities for normal use.

Lighting management
1. Gas station lighting includes two types of lighting and identification lights. Among them: the lighting lamp includes the lighting for the area such as business premises, living room, auxiliary room, toilet, road, and other business premises; the signage lamp includes light boxes such as cornices, advertisements, signs, signs, instructions, etc.
2. The lighting shall be managed in a separate way and used in sections; the lighting shall be opened to meet the operational needs, and the requirements for energy saving and consumption reduction shall be considered.
3. The lighting facilities should be regularly maintained and maintained in time to ensure normal use; the lamps should be replaced in time.
Send a message
Have Questions? Contact Us

We are always ready to help you !

  • Call Us :

    Tel : +86 15625117002

    Fax : +86 15625117002

  • Call Us :

    Email : gzguose1@guose.com.cn

    Skype : live:.cid.f1c890457f29e9f1

  • Address :

    NO.15-1 East,the HeShun in dustral Development Zone,Lishui in Nanhai ,Foshan city,Guangdong province
    Address of Australia branch: 326 Parramatta Road Stanmore, NSW 2048 Sydney, Australia

welcome to Guose
You can contact us any way that is convenient for you. We are available 24/7 via fax, email or telephone.

Home

Products

about

contact